| Specification Parameter | Technical Details |
|---|---|
| Model / Series | CC-W11-A Conductivity Sensor (CC-W Series) |
| Key Measurements | Water Electrical Conductivity (EC) & Media Temperature |
| Cell Constant Range Matrix | • K=0.01: 0∼20 μS/cm • K=0.1: 0∼200 μS/cm • K=1: 0∼4000 μS/cm • K=10: 0∼20 mS/cm • K=30: 0∼300 mS/cm |
| Measurement Accuracy | ±2% FS |
| Temperature Compensation Profile | 0∼60°C automatic NTC10K loop (Enabled via RS485 digital output only) |
| Resolution Matrix | 0.01 / 0.1 / 1 μS/cm & 0.01 / 0.1 mS/cm (Dependent on selected K constant) |
| Signal Output Interface | Simultaneous Dual Output: RS485 (Modbus-RTU) & 4∼20 mA concurrent loop |
| Power Supply Voltage | 12 VDC |
| Chassis Body Material Armor | Rugged PPS housing structure with premium anti-corrosion setup for deep buried immersion |
| Cable Length | Default kit includes 5m heavy-duty shielded cable (Fully customizable configurations available upon request) |
| Tailored OEM/ODM Capability | • Hardware Upgrades: Supports optional dedicated structural mounting brackets for secure field deployments. • Brand Customization: Custom silk-screen or laser-engraved logo branding available. • Technical Adaptation: Tailor-made technical parameters, adjustable multi-K cell constant configurations, and private-label colored packaging designs. |
| Applications | Engineered for boiler feed water monitoring, pure water purification grids, industrial chemical processing, wastewater treatments, environmental river telemetry, and advanced hydrological stations. |
To request the complete PDF technical specifications, please submit your inquiry below.