| Specification Parameter | Technical Details |
|---|---|
| Model / Series | CC-E11 Laser Particulate Matter Sensor (CC-E Series) |
| Measurement Principle | Laser Scattering Principle with Continuous Particle Size Distribution & Mass Concentration Conversion |
| Particulate Matter Measurement & Performance Specifications | |
| Measured Particle Sizes | PM1.0, PM2.5, PM10, and TSP |
| PM2.5 & PM10 Effective Range | 0 to 1000 µg/m³ |
| TSP Effective Range | 0 to 2000 µg/m³ |
| Mass Concentration Resolution | 1 µg/m³ |
| Response Time | < 2 s |
| Visual Status Indicator | Integrated Color-Changing Breathing LED Light for Real-Time Air Quality Threshold Alert |
| Electrical, Communication & Mechanical Configurations | |
| Output Signal & Interface | RS485 (Modbus-RTU) |
| Power Supply | 12 to 24 VDC |
| Operating Environment | -30°C to +70°C, 0% to 95% RH (Non-condensing) |
| Base Material | Aluminum Alloy |
| Cable Length | 3 m standard cable (Customizable lengths available upon request) |
| Tailored OEM/ODM Capability | • Brand Customization: Custom silk-screen or laser-engraved logo branding available. • Packaging Options: Private-label custom protective packaging and calibration certificates. • Technical Adaptation: Customizable LED alarm thresholds, cable lengths, and communication protocols. |
| Applications | Smart city & smart streetlight air quality monitoring, construction site dust control, industrial workshop particulate monitoring, urban atmospheric networks, and environmental research. |
Product Overview
The CHAOSENSOR CC‑E11 Laser Particulate Matter Sensor is an outdoor‑grade dust‑monitoring transmitter adopting laser‑scattering optical detection principle. It is designed for real‑time continuous measurement of particulate‑matter mass‑concentration including PM2.5, PM10 and TSP. Built‑in fan‑driven sampling structure draws ambient air into optical detection chamber; laser light scatters on airborne dust particles, and photoelectric sensor converts scattered‑light signals into mass‑concentration values. Equipped with weather‑resistant enclosure for long‑term unattended field deployment, it delivers processed particulate‑matter data via RS485 Modbus‑RTU digital interface, easily integrating with data loggers, SCADA and environmental IoT gateways. Explore our full‑range air‑quality monitoring instruments on our multi‑parameter air quality sensors page.
Core Working Principle
CC‑E11 laser particulate‑matter sensor operates on laser light‑scattering principle. Ambient air is steadily drawn into the sealed optical cavity by built‑in sampling fan. Laser diode emits collimated light beam; airborne dust particles generate light‑scattering signals when passing through detection zone. Photo‑detector captures scattered‑light pulses; internal MCU performs signal processing and particle‑mass‑conversion algorithm to output PM2.5, PM10 and TSP concentration results. Standard RS485 Modbus‑RTU protocol transmits measurement datasets to upper‑level acquisition systems. Internal anti‑dust design reduces optical‑contamination rate to extend service‑life under high‑dust field‑conditions.
Key Features & Engineering Advantages
- Multi‑Channel Particulate Measurement: Simultaneously measures PM2.5, PM10 and TSP mass‑concentration, meeting general ambient‑air and fugitive‑dust monitoring requirements.
- Laser‑Scattering Optical Detection: Mature optical dust‑sensing solution, fast response for dynamic‑change of ambient particulate‑pollutant concentration.
- Built‑In Sampling Fan: Active air‑intake sampling guarantees stable airflow entering detection chamber, improving sampling representativeness for outdoor deployment.
- Outdoor‑Resistant Mechanical Housing: Weather‑proof enclosure structure, adapts to complex outdoor environment for long‑term unmanned running.
- Industrial‑Standard Digital Interface: RS485 Modbus‑RTU output, compatible with environmental data‑loggers, PLC and IoT‑gateway hardware for smart‑city monitoring networks.
- Wide‑Voltage Industrial Power: 12‑24 VDC power‑supply, supports solar‑battery off‑grid remote‑site deployment and cabinet‑powered weather‑station setups.
- Complete OEM / ODM Customization: Custom silk‑screen / laser‑engraved logo marking, private‑label packaging, customizable cable‑lengths, connector‑types and communication‑protocol adaptation for tender‑grade bulk‑project orders.
Sensor Selection Guide: Laser‑Scattering Particulate‑Matter Sensors
CHAOSENSOR supplies multiple particulate‑matter‑monitoring hardware for different monitoring‑grade requirements:
- CC‑E11 Laser Particulate Matter Sensor: Stand‑alone laser‑scattering dust transmitter. Focused on PM2.5 / PM10 / TSP measurement. Suitable for distributed‑grid ambient‑air monitoring, construction‑site fugitive‑dust alert scenarios when you only need particulate‑data.
- CC‑E‑G12 Multi‑Parameter Air Quality Sensor: Modular multi‑gas + integrated PM measuring unit; choose when you require simultaneous gas‑pollutant plus dust‑parameter acquisition.
- High‑grade reference‑gravimetric monitoring station: Cabinet‑type active‑sampling reference station for audit‑level high‑accuracy dust‑calibration purpose, higher total‑system cost.
Select CC‑E11 if your primary monitoring objective is particulate‑matter concentration. Pair it with gas sensors, meteorological instruments from multi‑parameter air quality sensors page to build comprehensive outdoor environmental‑monitoring nodes.
Typical Industrial Applications
- Smart‑City Distributed Ambient‑Air Monitoring: Large‑scale grid‑layout particulate‑pollutant monitoring for urban environmental‑quality assessment.
- Construction‑Site & Quarry Fugitive‑Dust Supervision: Real‑time dust‑concentration monitoring for construction sites, mines and stock‑yard dust‑emission early‑warning systems.
- Industrial‑Park Boundary Environmental‑Monitoring: Perimeter dust‑pollutant observation for chemical‑industrial and manufacturing‑plant zones.
- Road‑Side Traffic‑Related Dust Telemetry: Road‑side node deployment for traffic‑induced particulate‑emission data‑collection.
- Automatic‑Weather‑Station Expansion Module: Add particulate‑matter‑monitoring function for existing unmanned weather‑station networks.
Installation & Field‑Deployment Guidelines
- Mounting‑Site Selection: Install on open representative‑ambient‑air position; stay away from direct dust‑sources, exhaust outlets and obstructions causing airflow‑distortion.
- Mount Posture: Keep sensor body upright; guarantee unobstructed air‑inlet and air‑outlet to ensure normal fan‑sampling performance.
- Power & Communication Wiring: Use 12‑24 VDC power‑supply; deploy shielded cable for RS485 Modbus‑RTU wiring to suppress electromagnetic‑interference.
- Routine Maintenance: Periodically inspect and clean air‑inlet filter; heavy‑dust sites will accelerate filter‑clogging, scheduled cleaning prevents sampling‑flow‑degradation and measurement‑bias.
- Condensation Note: Avoid long‑term direct water‑splashing onto sensor unit; high‑humidity plus condensation may affect optical‑chamber performance.
- Surge‑Protection Recommendation: Equip power‑and‑signal‑lines with lightning‑surge‑protection hardware for thunder‑prone outdoor‑locations to protect sensor and backend data‑acquisition equipment.
Frequently Asked Questions (FAQ)
1. What particulate‑matter parameters can CC‑E11 laser particulate‑matter sensor measure?
It supports real‑time simultaneous measurement of PM2.5, PM10 and TSP mass‑concentration for outdoor ambient‑air and fugitive‑dust monitoring scenarios.
2. What measurement principle does CC‑E11 adopt?
It uses laser‑scattering optical detection principle with built‑in sampling fan for active air‑intake sampling, converting particle‑scattered‑light signals into particulate‑mass‑concentration values.
3. What output‑interface does CC‑E11 support?
Standard RS485 Modbus‑RTU digital output, compatible with mainstream environmental‑data‑loggers, PLC and industrial‑IoT‑gateway devices.
4. Does CC‑E11 work together with multi‑parameter air‑quality sensors?
Yes. It can work independently or collaborate with multi‑gas sensors and meteorological instruments from our multi‑parameter air quality sensors page to build full‑featured environmental‑monitoring nodes.
5. Are OEM / ODM custom‑services available for CC‑E11?
Yes. Custom logo‑marking, private‑label packaging, custom cable‑lengths, connectors and communication‑protocol‑adaptation are supported for bulk‑order and tender‑project‑requirements.