Specification Parameter Technical Details
Model / Series CC-WL07 Rod-Type Hydrostatic Level Transmitter (CC-WL Series)
Measurement Principle Diffused Silicon Hydrostatic Pressure Sensing with Integrated Anti-Interference Chip
Level Measurement & Performance Specifications
Measurement Range0–0.5 m, 0–1 m, 0–2 m, 0–3 m (Custom ranges available within 0.5–3 m)
Measurement Accuracy±0.2% FS, ±0.5% FS
Temperature Drift±0.03% FS/°C
Overload Capacity< 1.5 × Full Scale (FS)
Measured MediaLiquids compatible with 304/316 stainless steel and cable materials
Media Temperature0°C to +350°C
Electrical, Communication & Mechanical Configurations
Output Signal Options 4 to 20 mA, 0 to 5 V, 0 to 10 V
Power Supply 12 to 24 VDC
Display Options Optional Local LCD Digital Display or Blind (Non-Display) Version
Operating Ambient Temperature -30°C to +80°C
Ingress Protection & Encapsulation IP68 (Submersible probe rated for long-term immersion) | Silicone Gel Potted Circuitry for Moisture & Corrosion Protection
Probe Material & Dimensions 304 Stainless Steel Probe (316L Stainless Steel optional) | Probe Diameter: Ø19 mm | Probe Length (L): Customizable
Process Connection M20 × 1.5 Male Thread (Standard; custom threads available)
Tailored OEM/ODM Capability • Brand Customization: Custom silk-screen or laser-engraved logo branding available.
• Packaging Options: Private-label custom protective packaging and calibration certificates.
• Technical Adaptation: Customizable probe insertion length (L), 316L stainless steel upgrade, thread sizes, and display configurations.
Applications High-temperature tanks, industrial boilers, chemical & oil storage vessels, water treatment plants, deep wells, and underground reservoirs.
To request the complete PDF technical specifications, please submit your inquiry below.

Product Overview

The CHAOSENSOR CC‑WL07 Rod‑Type Hydrostatic Level Transmitter is a submerged piezoresistive hydrostatic liquid‑level measuring probe. Based on hydrostatic‑pressure principle, it converts liquid‑column pressure into real‑time liquid‑level depth data for long‑term continuous monitoring of groundwater, wells, reservoirs, rivers and sewage tanks. The compact rod‑shaped stainless‑steel probe supports direct submersion into liquid media. It compensates for atmospheric pressure variation via vented cable structure, and delivers level measurement data through RS485 Modbus‑RTU or analog 4‑20 mA output, for easy integration with data‑loggers, PLC, SCADA and hydrological IoT acquisition platforms. Explore our full‑range hydrological and meteorological‑instrument lineup at our meteorological sensors page.

Core Working Principle

CC‑WL07 rod‑type hydrostatic level transmitter applies piezoresistive hydrostatic‑pressure sensing technology. The piezoresistive sensing diaphragm at the bottom of the rod probe bears pressure generated by the overlying liquid column. Built‑in vented cable eliminates atmospheric‑pressure interference, so the output pressure value purely corresponds to liquid‑level height. Internal circuit performs temperature compensation and signal conditioning, then outputs calibrated liquid‑level depth readings via analog 4‑20 mA or RS485 Modbus‑RTU digital bus. IP68 fully‑submersible sealed structure enables long‑time underwater deployment in natural water bodies and sewage environments.

Key Features & Engineering Advantages

  • Rod‑Type Compact Submerged Probe: Slim rod‑shape structure, suitable for installation inside boreholes, narrow wells and small‑diameter monitoring tubes without extra mounting brackets.
  • Atmospheric‑Pressure Compensation: Vented internal‑cable design automatically offsets barometric‑pressure fluctuation to guarantee true liquid‑level accuracy.
  • Dual‑Signal Output: Supports analog 4‑20 mA and RS485 Modbus‑RTU digital interface, compatible with legacy industrial systems and modern hydrological IoT networks.
  • Corrosion‑Resistant Submersible Construction: Stainless‑steel probe body with IP68 full‑submersion rating, adapts to fresh‑water, surface‑water and general sewage‑quality monitoring scenarios.
  • Stable Wide‑Temperature Operation: Integrated digital temperature‑compensation circuit reduces temperature‑drift for year‑round field unattended operation.
  • Flexible Industrial‑Grade Power: 12‑24 VDC wide‑voltage power‑supply, compatible with solar‑battery off‑grid remote hydrological‑monitoring stations.
  • Complete OEM / ODM Customization: Custom measuring‑range, vented‑cable lengths, connector types, laser‑engraved logo branding and private‑label export‑packaging for tender‑grade bulk‑project orders.

Sensor Selection Guide: Hydrostatic Level Transmitter Options

CHAOSENSOR provides multiple liquid‑level‑monitoring solutions for different hydrological‑project requirements:

  • CC‑WL07 Rod‑Type Hydrostatic Level Transmitter: Slim rod‑style submerged probe. Best‑suited for borehole‑well, narrow‑pipe and limited‑space liquid‑level monitoring; easy deployment for groundwater observation networks.
  • Cable‑type submersible level sensor: Conventional drop‑in type for open reservoirs, river channels, wider tanks; less fit for small‑diameter borehole tubes.
  • Non‑contact radar / ultrasonic level meter: Above‑water non‑contact installation, no submersion required; higher cost and susceptible to steam, foam and water‑surface wave interference.

Select CC‑WL07 when you need reliable submerged level‑measurement in narrow‑borehole or well‑monitoring scenarios. Pair it with tipping‑bucket rain gauge and meteorological sensors from meteorological sensors page to build a complete hydrological‑observation station.

Typical Industrial Applications

  • Groundwater & Borehole‑Well Monitoring: Long‑term submerged liquid‑level observation for groundwater resource investigation and underground‑water‑level dynamic tracking.
  • Reservoir, Lake & River Hydrology: Continuous water‑level logging for reservoir dispatch, river‑regime observation and flood‑risk early‑warning systems.
  • Sewage‑Treatment & Waste‑Water Tanks: Liquid‑level monitoring for sewage‑works pools and industrial waste‑water collection tanks.
  • Agricultural Water‑Conservancy Projects: Irrigation‑pond and canal water‑level monitoring for farmland water‑resource management.
  • Automatic Hydrological‑Meteorological Station Retrofit: Add liquid‑level‑measuring function for unmanned hydrological‑monitoring networks.

Installation & Field‑Deployment Guidelines

  • Submersion Installation: Lower the rod‑type probe to stable measuring depth; keep probe bottom away from sediment‑deposit layer to avoid silt covering the pressure‑sensing diaphragm.
  • Vented‑Cable Protection: Protect vented cable breathing tube; keep upper‑end vent opening dry, never submerge the vent section into water, otherwise pressure‑compensation will fail.
  • Cable Strain Relief: Fix cable with slack margin; avoid direct pulling force acting on probe‑cable joint to prevent internal vent‑tube damage.
  • Power & Communication Wiring: Adopt 12‑24 VDC power‑supply; deploy shielded cable for RS485 Modbus‑RTU wiring to suppress electromagnetic‑field interference.
  • Routine Maintenance: Periodically pull‑out probe and clean surface diaphragm of sediment, biofouling and attachments which may affect pressure‑sensing performance.
  • Surge‑Protection Recommendation: Fit lightning surge‑protection hardware for power‑and‑signal lines at thunder‑prone outdoor locations to protect transmitter and backend data‑acquisition equipment.

Frequently Asked Questions (FAQ)

1. Why does CC‑WL07 hydrostatic level transmitter adopt vented‑cable design?
The vented‑cable realizes atmospheric‑pressure compensation, eliminating barometric‑pressure change interference and ensuring accurate liquid‑level readings under varying weather conditions.

2. What output‑signals are supported for CC‑WL07?
Dual outputs: analog 4‑20 mA and RS485 Modbus‑RTU digital interface, compatible with mainstream hydrological data‑loggers, PLC and industrial‑IoT‑gateway hardware.

3. Can CC‑WL07 be used in small‑diameter borehole‑wells?
Yes. Slim rod‑type probe mechanical dimension is optimized for narrow‑borehole and monitoring‑tube deployment, which is its core advantage compared with conventional cable‑type level sensors.

4. What should be noticed for vented‑cable in field‑site?
The breathing‑vent end of vented‑cable must be kept above water and dry. If vent opening gets submerged or blocked, atmospheric‑pressure compensation will fail and produce large measurement deviation.

5. Does CHAOSENSOR provide OEM / ODM customization for CC‑WL07?
Yes. Custom measuring‑ranges, vented‑cable lengths, connectors, logo‑marking and private‑label‑packaging are supported for bulk‑order and tender‑project‑requirements. You may combine it with other hydrological‑meteorological instruments found on our meteorological sensors page for full‑featured hydrological‑observation‑station setups.