Your location:
> Product Details
CC-M200 Distributed photovoltaic power generation environmental monitoring system


Product solution introduction and application

1. Scope of application of the scheme 
Distributed photovoltaic power generation refers to photovoltaic power generation facilities that are built and operated at or near the user's site, mainly for self-use on the user side, with excess electricity connected to the grid and balanced and regulated in the distribution network system. In order to ensure the normal operation and data analysis of photovoltaic power stations, it is usually necessary to equip distributed photovoltaic power generation environmental monitoring systems to monitor indicators such as total solar radiation, ambient temperature, wind speed and direction, and photovoltaic module temperature. The distributed photovoltaic power generation environmental monitoring system can be connected to the monitoring system, which displays, records and analyzes the data of the environmental monitoring system. It can also be connected to the inverter control system, and the control system analyzes the sensor data to ensure the effective operation of the photovoltaic power station.

2. Product Description

It adopts a new integrated high-integration design, and the overall weight and installation time are 30% of those of conventional weather stations. Ultrasonic wind direction and wind speed are used to replace mechanical sensors, which greatly reduces the repair caused by mechanical wear while improving accuracy. It adopts a high-stability solar total radiation sensor with perfect cosine characteristics, fast response, zero offset and wide temperature response performance to ensure accurate and stable radiation data. Our company has many years of rich experience in serving domestic and foreign photovoltaic power station users, with sufficient sensor inventory, complete production lines, mature instrument and equipment debugging technical capabilities, comprehensive after-sales tracking services, and fast logistics and transportation systems. (Note: The solar total radiation sensor can be equipped with imported sensors, with product-related certificates) 
III. Product implementation specifications 
The site selection of distributed photovoltaic power generation environmental monitoring systems needs to consider many factors, and the site should be established in a place that is not shaded from sunrise to sunset throughout the year. Based on international observation methods, national observation specifications, power industry standards and many years of rich experience in site selection and installation and commissioning of environmental monitoring systems, our company provides detailed and professional specification guidance documents to relevant personnel of photovoltaic power stations.

Product Technical Parameters

model

CC-M200

powered by

DC12V

Output

RS485 MODBUS RTU protocol

Dimensions

-

Power supply

Solar power supply/ DC12V/AC220V/UPS

Baud rate

4800~115200 Default baud rate: 9600

weight

-

Shell material

-

Average power consumption

Operating temperature

-30℃~+70℃

Storage temperature

-40℃~+80℃

Operating humidity

0~100%RH

Protection level

IP65

Communication Mode

Wifi/GPRS/RS485/wireless point-to-point

Output aviation plug

IP68 SP13-6

Data receiving mode

Wireless data cloud platform APP/PC/webpage Wired stand-alone software Secondary development communication interface

Sensor expansion

support

Loading form

Fixed bracket 1.5m/3m/6m Portable bracket 2.2m

Detection data parameters

Sensor Name

Measuring range

Accuracy

Resolution

Ambient temperature

-40~123.8℃

±0.1℃

0.1℃

Ambient humidity

0~100%RH

±2%RH

0.1%RH

Maximum temperature

-40~123.8℃

±0.1℃

0.1℃

Minimum temperature

-40~123.8℃

±0.1℃

0.1℃

Dew point temperature

﹣40~123.8℃

±0.1℃

0.1℃

Wind speed

0~60m/s

±2% (≤20m/s), ±2%+0.03V m/s (>20 m/s)

0.1m/s

2-minute wind speed

0~60m/s

±2% (≤20m/s), ±2%+0.03V m/s (>20 m/s)

0.1m/s

10-minute wind speed

0~60m/s

±2% (≤20m/s), ±2%+0.03V m/s (>20 m/s)

0.1m/s

wind direction

0~359°

±2°

Air pressure

300~1100hPa

±0.12hPa

0.1hPa

Component temperature

-40~100℃

±0.1℃

0.1℃

Slant total radiation

0~2000w/m²

3%

1w/m²

Total daily cumulative tilt radiation

0~999.9MJ/m²

3%

0.1MJ/m²

Monthly cumulative total tilt radiation

0~9999MJ/m²

3%

1MJ/m²

Annual cumulative tilted total radiation

0~9999MJ/m²

3%

1MJ/m²

rainfall

0~999

≤2

                             mm

Install:



Design and implementation standards

Guide to Meteorological Instruments and Methods of Observation World Meteorological Organization (WMO) Commission for Instruments and Methods of Observation (CIMO) and IEC (International Electrotechnical Commission)

State Grid Corporation of China Enterprise Standard Q/GDW 617-2011 "Technical Regulations for Photovoltaic Power Station Access to the Grid"

State Grid Corporation of China Enterprise Standard Q/GDW 618-2011 "Test Procedures for Photovoltaic Power Station Access to the Grid"

"Technical Specifications for Acceptance of Grid-connected Photovoltaic Power Generation System Projects"

《QX/T 61-2007 Specification for Ground Meteorological Observation》

"QX/T-2000Ⅱ Automatic Weather Station Industry Standard"

"QX/T74-2007 Technical Specifications for Meteorological Observation and Data Review and Correction in Wind Farms"

The default Modbus device address is 1.

MODBUS message: 01 03 00 00 00 0e C4 0E 
The default baud rate is 9600, 8 data bits, no parity check, and 1 stop bit (9600, 8, N, 1)

Table 1 Real-time data (Read only, function code 03)

Modbus Address

Serial port baud rate

Parameter settings

Communication

Latitude and longitude

#1

9600

8 N 1

RS485 Communication

Device Address

Parameter name

Decimal Places

unit

0x0000

wind direction

0

°

Set 
according to 

the local 

real-time 

longitude 

and latitude

0x0001

Wind speed

1

m/s

0x0002

Ambient temperature

1

0x0003

Maximum temperature

1

0x0004

Minimum temperature

1

0x0005

Ambient humidity

1

%RH

0x0006

Dew point temperature

1

0x0007

Air pressure

1

h

0x0008

Total radiation

0

W/m2

0x0009

Total radiation daily accumulation

2

MJ/m2

0x000a

Total radiation monthly cumulative

0

MJ/m2

0x000b

Total annual radiation

0

MJ/m2

0x000c

Sunshine hours

1

h

0x000d

Component temperature

1

save in phone
Copyright © China Zhejiang Chao Sensor Group
Disclaimer: Some of the information and pictures on this site are from the Internet and contributed by netizens. If there is any infringement, please contact customer service in time, and we will deal with it as soon as possible.
Powered by Feedback Manage