Measuring medium: liquid or gas (compatible with contact material)
Overall material: Diaphragm 316L stainless steel (contact) Process connection 316L stainless steel (contact)
Housing die-cast aluminum
Pressure range: 0~ 10kPa~ 10MPa (see range selection table for details)
Pressure mode: gauge pressure
Output signal: 4~20mA, RS485 (standard Modbus-RTU protocol), (0. 5~2.5VDC, 0~10VDC, 0~5VDC, 1~5VDC customized)
Supply voltage: 12~36VDC conventional 24VDC
Intrinsically Safe
15~36VDC conventional (with display or output 0~10VDC) 3~5VDC custom (output is 0.5~2.5VDC/RS485)
Accuracy class: 0.1%FS (range ≥100kPa customized) 0.25%IFS (range ≥100kPa default)
0.5%FS
(l0kPa≤range<100kPa default) The display accuracy of the meter head is 0.5%PS, and the digital tube (LED) display
Working conditions: medium temperature -40~130°C ambient humidity
0%~-95%RH (no condensation and no condensation)
Ambient temperature -40~85C (explosion-proof environment -20~40C)
Temperature compensation: -10~ 70C (accuracy is 0.25%FS, 0.5%FS)
-40~80C (accuracy is 0.1%FS)
Explosion-proof grade: ExiaICT6 (limited current output without display) Note: Intrinsic safety must be powered by a safety barrier or an intrinsically safe power supply
Shock resistance: 10g (20. ..2000Hz)
Overload capacity: 200% full scale
Response frequency: analog signal output ≤ 500Hz, digital signal output ≤ 5Hz
Stable performance: ±0.1% FS/year
Temperature drift: ±0.01%FS/C (within temperature compensation range)
Overall weight: ≈880g
Protection class: IP65 Note: The above protection class is achieved after the electrical connection is complete
Power range: current type≤0.02Us(W) digital type≤0015Us(W) voltage type≤0.008Us(W)
Voltage type (output 0.5~2.5)≤0.001Us (W) Note: Us=supply voltage
Load characteristics: Current type load ≤{ (Us- 7.5) +0.02 (Us=supply voltage) } 0 Voltage type load ≥100k 0
(4~20) mA DC