| Specification Parameter | Technical Details |
|---|---|
| Model / Series | CC-A26 TDR Soil Moisture Sensor (CC-A Series) |
| Key Measurements Matrix | Soil Volumetric Water Content (VWC) |
| Soil Moisture Sensing & Accuracy Matrix | |
| Measurement Principle | Time Domain Reflectometry (TDR) |
| Measurement Range | 0 – 60% m³/m³ (0 to Saturated Water Content) | Optional: 0 – 100% |
| Measurement Accuracy | < ±0.03 m³/m³ (±3% VWC) (Under EC ≤ 0.5 mS/cm, bulk density ≤ 1.55 g/cm³, 0%–50% standard calibration) |
| Resolution & Response | Resolution: 0.1% | Measurement Response Time: < 500 ms |
| Effective Sensing Zone | Measures soil volumetric water content within a 10 cm radius around the probe |
| Electrical, Output & Telemetry Configurations | |
| Output Signal | RS485 (Modbus-RTU protocol) | Transmission distance up to 1000 m (supports up to 32 nodes) |
| RS-485 Protocol Defaults | Baud Rate: 9600 bps | Data Frame: 8-N-1 | Default Device Address: 01 (Configurable) |
| Power Supply & Consumption | 12 – 24 VDC | Typical Current: 25 mA (Max ≤ 50 mA at 12 VDC) |
| Mechanical & Environmental Specifications | |
| Housing & Probe Material | Housing: ABS Engineering Plastic | Sensing Probes: 316 Stainless Steel (3-rod design, Ø3.5 mm × 110 mm) |
| Sensor Dimensions & Weight | Total Length: 161 mm (Body: 51 mm + Probe: 110 mm) × Width: 32 mm × Thickness: 20 mm | Weight: ≈ 350 g (including 5 m cable) |
| Ingress Protection (IP Rating) | IP68 Waterproof & Dust-tight (Engineered for long-term direct soil burial) |
| Operating Temperature | 0 to +45 °C (Suitable for outdoor field deployment) |
| Cable Length | 5 m standard waterproof cable (Customizable up to 1000 m upon request) |
| Customization & Field Applications | |
| Tailored OEM/ODM Capability | • Brand Customization: Custom silk-screen or laser-engraved logo branding available. • Packaging Options: Private-label custom colored packaging designs. • Technical Adaptation: Custom moisture measurement ranges (0–60% / 0–100%), cable lengths, and soil-specific calibration curves available upon request. |
| Applications | Precision agriculture & automated irrigation systems, soil hydrological telemetry, soil and water conservation monitoring, ecological research, greenhouse management, and smart agrometeorological stations. |
Product Overview
The CHAOSENSOR CC‑A26 TDR Soil Moisture Sensor is a high‑performance volumetric water content probe adopting Time Domain Reflectometry (TDR) principle, belonging to the CC‑A sensor series. It accurately measures soil volumetric water content (VWC) in the surrounding soil zone, delivering stable readings for soil moisture monitoring. Featuring a 3‑rod 316 stainless steel sensing structure and IP68 fully waterproof enclosure, this TDR soil moisture sensor supports long‑term direct burial in field soil. It outputs data via RS485 Modbus‑RTU digital bus, with transmission distance up to 1000 m and support for up to 32 sensor nodes on one bus. It is widely deployed in precision agriculture, automatic irrigation control, soil hydrological monitoring, ecological research, greenhouse management and agrometeorological stations. Browse our full‑range environmental and agrometeorological instruments at our meteorological sensors page.
Core Working Principle
CC‑A26 TDR soil moisture sensor works on Time Domain Reflectometry (TDR) technology. Electromagnetic pulses travel along the three stainless steel probe rods buried inside soil. The propagation speed of the pulse changes with the dielectric constant of the soil, which is dominated by soil water content. The onboard circuit records the signal reflection time and calculates volumetric water content of the soil. The sensor is factory calibrated and can support custom calibration curves for different soil types. Processed moisture data is packaged and transmitted through RS485 Modbus‑RTU to data loggers, IoT gateways and agrometeorological acquisition systems. The robust sealed structure prevents moisture and dust ingress for years of unattended underground operation.
Key Features & Engineering Advantages
- TDR Time Domain Reflectometry Technology: Reliable volumetric water content measurement, less sensitive to soil salinity interference compared with some capacitance sensors under proper calibration conditions.
- High Measurement Accuracy & Fast Response: Accuracy better than ±0.03 m³/m³ (±3% VWC) under standard calibration conditions; resolution up to 0.1%, response time below 500 ms for rapid soil moisture change capture.
- Adjustable Measuring Range: Standard range 0–60% m³/m³, optional 0–100% full range for saturated soil monitoring projects.
- 3‑Rod 316 Stainless Steel Probe: 3.5 mm × 110 mm probe rods, corrosion‑resistant for long‑term burial in natural soil; effective sensing radius of 10 cm around the probe.
- RS485 Modbus‑RTU Digital Output: 9600 bps, 8‑N‑1 by default, configurable address; up to 1000 m transmission length and 32 nodes per bus, easy for multi‑point soil moisture profile networking.
- IP68 Waterproof & Dust‑Tight Grade: ABS plastic housing with fully sealed design, built for permanent burial in soil.
- 12–24 VDC Wide Voltage Power Supply: Low power consumption, typical current 25 mA, max ≤50 mA at 12 VDC, compatible with solar‑powered remote field stations.
- Flexible OEM / ODM Customization: Custom logo marking, private‑label packaging, custom cable lengths up to 1000 m, custom measuring ranges and soil‑specific calibration curves for bulk tender projects.
Sensor Selection Guide: TDR Soil Moisture Sensors
CHAOSENSOR provides multiple soil monitoring sensors for different agricultural and hydrological observation needs:
- CC‑A26 TDR Soil Moisture Sensor: TDR‑based volumetric water content probe. Best choice for projects requiring reliable VWC measurement, suitable for precision irrigation, hydrological and ecological field research.
- Capacitance soil moisture sensor: Lower cost solution, more suitable for budget‑sensitive agricultural sites, but higher sensitivity to soil EC and texture variations.
- Multi‑parameter soil composite sensor: Integrates moisture, temperature and EC together; choose when you need simultaneous multi‑parameter soil monitoring.
Select CC‑A26 if you prioritize stable TDR volumetric water content data. Pair it with multi‑layer soil temperature sensors and meteorological instruments from meteorological sensors page to build a complete agrometeorological monitoring station.
Typical Industrial Applications
- Precision Agriculture & Automated Irrigation: Real‑time soil moisture feedback for intelligent irrigation control, saving water and optimizing crop growth conditions.
- Soil Hydrological Telemetry & Water Conservation: Soil water dynamic monitoring for watershed, soil erosion and water conservation research.
- Ecological & Field Research: Long‑term soil moisture dataset collection for ecosystem study and field experiment plots.
- Greenhouse Intelligent Management: Greenhouse substrate moisture monitoring for vegetable and flower planting management.
- Smart Agrometeorological Stations: Add soil moisture observation function for unmanned agrometeorological monitoring networks.
Installation & Field‑Deployment Guidelines
- Probe Insertion Method: Make a pre‑drilled hole matching the probe size; insert the three‑rod probe vertically into undisturbed soil, ensure full contact between probe rods and surrounding soil without air gaps.
- Sensing Zone Note: The sensor measures soil moisture within a 10 cm radius around the probe; avoid placing it near rock, large plant roots or artificial barriers that distort soil conditions.
- Power & Communication Wiring: 12–24 VDC power supply; use shielded cable for RS485 Modbus‑RTU wiring to reduce electromagnetic interference; observe the 32‑node limit per bus segment.
- Operating Temperature Range: Keep working environment within 0 to +45 °C for optimal performance; avoid direct high‑temperature sunlight exposure on the sensor housing above ground.
- Cable Protection: Standard 5 m waterproof cable; protect the cable from sharp stones, rodents and tensile damage; longer custom cables are available on request.
- Surge‑Protection Recommendation: Install lightning surge protection for power and signal lines for outdoor remote sites in thunderstorm‑prone regions.
Frequently Asked Questions (FAQ)
1. What measurement principle does CHAOSENSOR CC‑A26 adopt?
CC‑A26 uses Time Domain Reflectometry (TDR) principle to measure soil volumetric water content (VWC).
2. What is the measurement range and accuracy of CC‑A26?
Standard range 0–60% m³/m³, optional 0–100%. Accuracy is better than ±0.03 m³/m³ (±3% VWC) under standard calibration conditions (EC ≤ 0.5 mS/cm, bulk density ≤ 1.55 g/cm³, 0%–50%).
3. What output interface and protocol does CC‑A26 support?
RS485 Modbus‑RTU, default 9600 bps, 8‑N‑1, address configurable; maximum transmission distance 1000 m, up to 32 nodes on one bus.
4. Is CC‑A26 suitable for long‑term burial in soil?
Yes. IP68 waterproof and dust‑tight, 316 stainless steel probe rods, designed for long‑term direct soil burial.
5. Can I customize the cable length and calibration for CC‑A26?
Yes. Custom cable length up to 1000 m, measuring ranges and soil‑specific calibration curves are available. OEM and private‑label services are supported for bulk orders. Combine it with other meteorological sensors from our meteorological sensors page for full agrometeorological monitoring solutions.