Chaosensor CC-E10 Industrial Micro Differential Pressure Sensor

CC-E10 industrial micro differential pressure sensor, piezoresistive transmitter for HVAC cleanroom pressure monitoring
Specification Parameter Technical Details
Model / Series CC-E10 Differential Pressure Transmitter (CC-E Series)
Measurement Mode & Principle Differential, Micro-Differential, Gauge, and Negative/Vacuum Pressure | Piezoresistive Silicon Chip with Integrated Conditioning Circuit
Pressure Measurement & Performance Matrix
Standard Measuring Ranges • Unidirectional: 0–100 Pa, 0–200 Pa, 0–500 Pa, 0–1 kPa, 0–2 kPa, 0–5 kPa, 0–10 kPa
• Bidirectional: ±100 Pa, ±200 Pa, ±500 Pa, ±1 kPa, ±2 kPa, ±5 kPa, ±10 kPa
• Custom Ranges: Anywhere within -100 to +100 kPa
Accuracy (Combined) ±0.2% FS or ±0.5% FS (selectable)
Zero Temperature Drift ±0.03% FS/°C
Sensitivity Temperature Drift ±0.03% FS/°C
Over-Pressure Limit 300% FS
Max. Static Pressure ±10 kPa (for ≤1 kPa ranges); ±20 kPa (for 2 kPa); ±50/±55 kPa (for 5 kPa); ±100 kPa (for 10 kPa)
Measuring Medium & Wetted Materials Non-corrosive gases | Silicon chip, LY12 aluminum alloy, NBR (nitrile rubber) seals
Electrical & Environmental Specifications
Signal Output Options • 2-Wire Current: 4 – 20 mA, 0 – 10 mA
• 3-Wire Voltage: 1 – 5 V, 0 – 5 V, 0 – 10 V
• Digital Interface: RS-485 (Modbus-RTU) (Note: Protocol manuals differ between non-display and LCD versions; please inquire separately)
Power Supply Voltage 10 – 32 VDC (24 VDC nominal)
Electrical Protection Current-limiting, voltage-limiting, and reverse-polarity protection (current output only)
Compensated Temperature 0 to +50 °C
Medium Temperature -20 to +45 °C
Ambient Operating Temperature -20 to +45 °C
Mechanical Dimensions & System Configurations
Housing & Dimensions • Standard Version (Without Display): 65 × 60 × 27.5 mm (Overall length incl. barbs: 102.9 mm)
• Local LCD Display Version: 85 × 69.1 × 33 mm (Overall length incl. barbs: 124.1 mm)
Process Connection Dual Ø8 mm hose barbs (M10 thread) or optional quick couplings
Tailored OEM/ODM Capability • Brand Customization: Custom silk-screen or laser-engraved logo branding available.
• Packaging Options: Private-label custom colored packaging designs.
• Technical Adaptation: Fully customizable pressure ranges (within -100 to +100 kPa), accuracy grades, and output signal configurations.
Applications Continuous differential and gauge pressure monitoring across hospital and laboratory cleanrooms, building HVAC systems, industrial automation, process control, water treatment plants, petrochemical facilities, and power stations.
To request the complete PDF technical specifications or RS-485 Modbus protocol manual, please submit your inquiry below.

Product Overview

The CHAOSENSOR CC‑E10 Differential Pressure Transmitter is an industrial‑grade high‑precision micro‑differential pressure transmitter from the CC‑E product series. Built upon advanced piezoresistive silicon sensing chip and integrated signal‑conditioning circuitry, it measures differential, micro‑differential, gauge and negative/vacuum gas pressure across measuring ranges from ‑100 kPa to +100 kPa. The unit undergoes precise zero‑point and sensitivity temperature compensation for low thermal drift. Two housing options are available: compact non‑display variant for space‑limited installation and LCD local‑display version for on‑site visual readout. With high static‑pressure resistance, fast dynamic‑response and strong EMI immunity, CC‑E10 fits clean‑room monitoring, HVAC systems, water‑treatment, petrochemical facilities, power‑plants and light‑industrial process‑control applications. Seamless integration is supported for PLC, DCS and SCADA systems via rich signal‑output options. Explore our full portfolio of industrial transmitters and environmental sensors at our meteorological sensors page.

Core Working Principle

CC‑E10 differential pressure transmitter adopts piezoresistive silicon sensing technology. Gas pressure is fed into the high‑pressure (H) port and low‑pressure (L) port simultaneously. The pressure difference deforms the isolated silicon diaphragm, changing resistance values of the internal Wheatstone‑bridge circuit. The on‑board ASIC performs amplification, linearisation and full temperature‑compensation for micro‑level raw signals, then converts pressure difference into standard analog current / voltage signals or RS‑485 Modbus‑RTU digital values. For LCD‑display models, processed pressure readings are rendered on the front local screen for direct on‑site inspection. Wetted components are compatible with most non‑corrosive gas media for long‑term stable field‑operation.

Key Features & Engineering Advantages

  • High‑Precision Piezoresistive Sensing Core: Selectable full‑scale accuracy ±0.2% FS or ±0.5% FS; low zero and sensitivity thermal drift at ±0.03% FS/°C, with substrate thin‑film‑resistor temperature‑compensation design.
  • Broad‑Range Pressure‑Measurement: Supports unidirectional, bidirectional, gauge and vacuum pressure; custom ranges configurable within ‑100 kPa ~ +100 kPa for micro‑pressure up to heavy‑differential‑pressure working conditions.
  • Robust Over‑Pressure & Static‑Pressure Resistance: Withstands momentary over‑pressure up to 300% FS; high tolerance for line static‑pressure, effectively prevents diaphragm damage caused by system pressure surges.
  • Multi‑Format Industrial Outputs: 2‑wire current‑loop (4‑20 mA, 0‑10 mA), 3‑wire voltage outputs (1‑5 V, 0‑5 V, 0‑10 V), plus RS‑485 Modbus‑RTU digital interface, compatible with DCS, PLC and SCADA platforms.
  • Dual Mechanical Housing Options: Compact non‑display enclosure for space‑constrained panel‑mount scenarios; LCD display version providing local real‑time pressure readout and on‑site parameter configuration. Both versions feature Ø8 mm hose‑barb pressure ports with optional quick‑coupling fittings.
  • Wide Power Input & Electrical Protection: 10‑32 VDC supply (24 VDC nominal); current‑limiting, voltage‑limiting and reverse‑polarity protection built‑in for current‑output variants, improving field anti‑mis‑wiring reliability.
  • Comprehensive OEM / ODM Customization: Custom pressure measuring‑ranges, port‑fitting types, output‑signal configurations and private‑label branding & export‑packaging for bulk‑order and tender‑grade projects.

Sensor Selection Guide: Differential Pressure Transmitter Options

CHAOSENSOR provides multiple pressure‑measurement transmitters for different industrial‑process requirements:

  • CC‑E10 Differential Pressure Transmitter: Piezoresistive gas‑oriented differential / micro‑differential pressure transmitter. Choose for HVAC duct‑pressure, clean‑room pressure‑gradient, cabinet differential‑pressure and non‑corrosive‑gas process‑monitoring; available in non‑display or LCD‑local‑display housing.
  • General‑purpose gauge‑pressure transmitter: Optimised for single‑port gauge‑pressure measurement, without high‑performance differential‑pressure dual‑port H/L structure.
  • Liquid‑media pressure transmitters: Designed for liquid‑process pressure monitoring, different wetted‑material configuration compared with CC‑E10 gas‑focused model.

Select CC‑E10 when you need accurate gas‑based differential‑pressure or micro‑differential‑pressure acquisition. Combine it with other industrial‑grade sensors from meteorological sensors page to construct complete process‑monitoring systems.

Typical Industrial Applications

  • HVAC & Building Ventilation Systems: Duct differential‑pressure monitoring, filter‑clogging detection, air‑handling‑unit pressure‑difference inspection for commercial‑building ventilation systems.
  • Clean‑Room & Controlled‑Environment Monitoring: Maintain and verify pressure‑gradient between adjacent clean‑room zones to prevent cross‑contamination.
  • Industrial Automation & Process‑Control: Differential‑pressure supervision for light‑industrial equipment, pipeline gas‑process monitoring.
  • Power‑Plant Auxiliary Monitoring: Air‑filter differential‑pressure monitoring and auxiliary‑gas‑circuit status inspection for power‑generation facilities.
  • Water‑Treatment & Petrochemical Light‑Process: Non‑corrosive gas‑circuit differential‑pressure measurement for water‑treatment workshops and petrochemical auxiliary‑gas‑loops.

Installation & Field‑Deployment Guidelines

  • Pressure‑Port Connection: Correctly distinguish High‑Pressure (H) port and Low‑Pressure (L) port; connect tubing to Ø8 mm hose‑barb fittings or optional quick‑coupling accessories; ensure tubing is free from blockage or serious leakage.
  • Mounting: Utilise built‑in mounting‑ears with Ø4 mm mounting holes for wall‑or‑panel fixing; keep transmitter in stable posture to avoid heavy mechanical‑shock.
  • Power & Signal Wiring: Operate within 10‑32 VDC (24 VDC nominal). Strictly follow wiring definition for 2‑wire / 3‑wire analog or RS‑485 Modbus‑RTU; use shielded cable for digital‑signal lines to reduce EMI interference.
  • Media Restriction: Only apply for non‑corrosive gas media matching wetted‑material compatibility (silicon chip, LY12 aluminium‑alloy, NBR seals).
  • Over‑Pressure Warning: Although supporting 300% FS momentary over‑pressure, avoid long‑term continuous over‑pressure operation to extend diaphragm service‑life.
  • Surge‑Protection Recommendation: Equip power‑and‑signal‑lines with surge‑protection components for lightning‑prone industrial‑field‑locations.

Frequently Asked Questions (FAQ)

1. What pressure types can CHAOSENSOR CC‑E10 differential pressure transmitter measure?
It supports differential pressure, micro‑differential pressure, gauge pressure and negative / vacuum pressure. Custom measuring‑ranges are available within ‑100 kPa to +100 kPa for non‑corrosive gas media.

2. What housing versions are offered for CC‑E10?
Two configurations: compact non‑display housing for space‑restricted installation; LCD local‑display version for on‑site real‑time pressure readout and parameter adjustment. Both are equipped with dual Ø8 mm hose‑barb pressure ports.

3. What output‑signals does CC‑E10 support?
2‑wire current‑loop (4‑20 mA, 0‑10 mA), 3‑wire voltage outputs (1‑5 V, 0‑5 V, 0‑10 V), and RS‑485 Modbus‑RTU digital interface for DCS, PLC and SCADA integration.

4. What is the power‑supply specification of CC‑E10?
Wide 10‑32 VDC power‑input with 24 VDC as nominal working voltage. Current‑output models integrate current‑limiting, voltage‑limiting and reverse‑polarity protection.

5. Are OEM / ODM custom‑services available for CC‑E10?
Yes. Custom pressure‑ranges, pressure‑port fittings, output‑signal modes and private‑label branding & packaging can be realised for bulk‑order and tender‑project‑needs. You may pair it with other industrial sensors found on our meteorological sensors page for complete process‑monitoring solutions.

This field is required.
This field is required.
This field is required.
This field is required.
This field is required.