CC-M02 Atmospheric Temperature, Humidity & Pressure Sensor

Chaosensor CC‑M01 Atmospheric Temperature and Humidity Sensor, outdoor air temperature relative humidity transmitter
Specification Parameter Technical Details
Model / Series CC‑M02 Atmospheric Temperature, Humidity and Pressure Sensor (CC‑M Series)
Key Measurements Matrix Atmospheric Temperature, Relative Humidity (%RH), Barometric Pressure
Measurement Performance Matrix
Sensing ElementDigital capacitive polymer (RH), band‑gap (T), and MEMS piezoresistive (P) sensing core
Temperature Measurement Range−30 ~ +70 °C (standard) / −40 ~ +60 °C (optional) / other ranges on request
Humidity Measurement Range0 ~ 100 %RH (non‑condensing)
Barometric Pressure Range100 to 1100 hPa
Temperature Accuracy±0.2 °C @ +25 °C
Humidity Accuracy±2 %RH @ 10 ~ 90 %RH
Barometric Pressure Accuracy±1 hPa @ +25 °C
Repeatability±0.1 °C / ±0.1 %RH
Long‑Term Stability< 0.04 °C per year / < 0.1 %RH per year
Response Time< 15 s (t63% in 1 m/s airflow)
Electrical & Output Configuration
Signal Output Options • Voltage: 0–2 V / 0–5 V / 0–10 V
• Current Loop: 4‑20 mA
• Digital Interface: RS‑485 (Modbus‑RTU) / SDI‑12
Power Supply Voltage 12‑24 VDC (Standard); 3.3 / 5 VDC (Optional)
Default Serial Configuration 9600 bps, 8‑N‑1, slave address 01
Operating Environment −55 ~ +70 °C ; ≤95 %RH (non‑condensing)
Mechanical & Physical Matrix
Radiation Shield UV‑stabilized multi‑plate shield (6‑plate standard; 8‑,10‑,11‑,12‑plate optional; Ø140 mm); equipped with adjustable threaded leveling feet
Mounting Hardware / Accessories Heavy‑Duty SS304 Stainless Steel U‑bolt Pole Clamps & L‑shaped Bracket Matrix; support pole, mast, plate or duct mounting
Tailored Mechanical Customization Shield geometry, probe extension length, mechanical mounting interfaces customizable (electrical specifications remain unchanged)
Product Features & Application Scope
Core Highlights • 3‑in‑1 factory‑calibrated sensing core, no on‑site calibration
• Full‑range linearization & thermal compensation for temperature, humidity and pressure
• Multi‑output compatible with data loggers, PLC and BMS systems
• Anti‑vibration compact housing, multiple mounting modes for diverse deployment
Applications Meteorological observation stations, building management, telecommunication rooms, clean workshops, greenhouses, warehouses, agricultural micro‑climate monitoring and environmental telemetry projects.
To request the complete PDF technical specifications, please submit your inquiry below.

Product Overview

The CHAOSENSOR CC‑M02 Atmospheric Temperature, Humidity and Pressure Sensor is a three‑in‑one meteorological probe from the CC‑M series, engineered to simultaneously capture air temperature, relative humidity and barometric pressure. It integrates three independent high‑performance sensing cores: digital capacitive polymer for humidity, band‑gap for temperature and MEMS piezoresistive chip for barometric pressure. Fully factory calibrated with full‑range linearisation and thermal compensation, it requires no on‑site calibration. Equipped with a Ø140 mm UV‑stabilized multi‑plate radiation shield with adjustable threaded leveling feet, this sensor minimizes solar radiation bias to deliver reliable outdoor atmospheric data. It supports versatile signal options including voltage, 4‑20mA current, RS485 Modbus‑RTU and SDI‑12, compatible with data loggers, PLC, SCADA and BMS platforms. It is widely deployed in meteorological observation stations, building management, telecom rooms, clean workshops, greenhouses, warehouses and agricultural microclimate telemetry projects. Browse our full meteorological and environmental instrument lineup at our meteorological sensors page.

Core Working Principle

CC‑M02 uses three separate sensing technologies for atmospheric monitoring. The capacitive polymer humidity element changes capacitance according to ambient water vapor concentration to calculate relative humidity. The band‑gap temperature core provides stable temperature readings with low long‑term drift. The MEMS piezoresistive sensing core converts atmospheric pressure variations into electrical signals for barometric pressure calculation. Built‑in signal conditioning circuitry performs linearisation and temperature compensation for all three parameters, and outputs calibrated values via the selected analog or digital interface. The multi‑plate radiation shield blocks direct sunlight while maintaining natural airflow around the sensing cavity, reducing solar heating error and ensuring representative climate measurement under non‑condensing field conditions.

Key Features & Engineering Advantages

  • 3‑in‑One Integrated Meteorological Measurement: Captures air temperature, relative humidity and barometric pressure in one compact unit, simplifying wiring and integration for automatic weather stations.
  • High Precision & Excellent Long‑Term Stability: Temperature accuracy ±0.2°C @25°C; humidity accuracy ±2 %RH @10–90 %RH; barometric pressure accuracy ±1 hPa @25°C. Repeatability reaches ±0.1°C / ±0.1 %RH; annual drift below 0.04°C and 0.1 %RH respectively.
  • Wide Measurement Ranges & Fast Response: Standard temperature range −30 ~ +70°C, optional −40 ~ +60°C or custom ranges; humidity 0–100 %RH (non‑condensing); pressure range 100–1100 hPa; response time less than 15 seconds (t63% at 1 m/s airflow).
  • Multiple Output Interfaces: Analog voltage (0–2V / 0–5V / 0–10V), 4‑20mA current loop, RS485 Modbus‑RTU and SDI‑12 digital output, supporting legacy analog and modern digital acquisition hardware.
  • UV‑Stabilized Multi‑Plate Radiation Shield: Ø140 mm shield, 6‑plate standard; 8/10/11/12‑plate optional, fitted with adjustable threaded leveling feet for easy leveling during installation.
  • Flexible Power Supply: Standard 12–24 VDC for industrial and field stations; 3.3 / 5 VDC low‑voltage version available as an option.
  • Robust Mounting Options: Supplied with heavy‑duty SS304 stainless steel U‑bolt pole clamps and L‑shaped bracket, supporting pole, mast, plate and duct mounting.
  • Customizable Mechanical Design: Support custom shield geometry, probe extension length and mechanical mounting interfaces while keeping electrical specifications unchanged; OEM and private‑label customization available for bulk tender projects.
  • Factory Pre‑Calibrated All Parameters: Full‑range linearisation and thermal compensation for temperature, humidity and pressure; anti‑vibration compact housing for long‑term unattended operation.

Sensor Selection Guide: Meteorological Climate Sensors

CHAOSENSOR provides multiple atmospheric monitoring sensors for different climate observation requirements:

  • CC‑M02 Temperature Humidity Pressure Sensor: Three‑parameter all‑in‑one weather probe with radiation shield, multi‑signal output. Best suited for standard meteorological stations and environmental telemetry projects that need barometric pressure data.
  • CC‑M01 Temperature and Humidity Sensor: Dual‑parameter T/RH version without pressure measurement, ideal for greenhouses, warehouses and BMS applications where pressure is not required.
  • Single‑parameter atmospheric transmitters: Independent temperature, humidity or barometric sensors for installations where each parameter needs separate placement.

Choose CC‑M02 when you need a ready‑to‑use three‑in‑one climate probe. Pair it with rainfall, wind speed and soil sensors from meteorological sensors page to build a complete automatic meteorological observation station.

Typical Industrial Applications

  • Meteorological Observation & Environmental Telemetry: Outdoor air temperature, humidity and barometric pressure monitoring for agrometeorological and weather monitoring networks.
  • Building Management Systems (BMS): Indoor ambient climate monitoring for HVAC control and building environment management.
  • Telecommunication & Server Rooms: Real‑time environmental monitoring for communication equipment and data cabinet spaces.
  • Cleanrooms & Industrial Workshops: Stable climate tracking for clean manufacturing and controlled production environments.
  • Greenhouses, Warehouses & Agricultural Microclimate: Climate monitoring for crop planting, goods storage and farm microclimate observation.

Installation & Field‑Deployment Guidelines

  • Radiation Shield Mounting: Install the radiation shield horizontally, adjust the threaded leveling feet for level placement; keep away from heat sources, walls and reflected sunlight to reduce radiation error.
  • Mounting Hardware: Use the SS304 U‑bolt and L‑bracket to fasten the sensor firmly on pole, mast or duct; avoid strong continuous mechanical vibration.
  • Wiring & Communication: Standard 12–24 VDC power supply; RS485 Modbus‑RTU defaults to 9600 bps, 8‑N‑1, slave address 01; use shielded cable for digital signal wiring to reduce EMI interference.
  • Operating Limits: Working environment −55 ~ +70°C, ≤95 %RH non‑condensing; avoid condensation and liquid water entering the sensing cavity.
  • Airflow Condition: Ensure natural airflow around the radiation shield; do not install inside fully enclosed housings that block air circulation.
  • Surge‑Protection Recommendation: Install lightning surge protection for power and signal lines when deployed at remote outdoor meteorological sites in thunderstorm‑prone areas.

Frequently Asked Questions (FAQ)

1. What parameters does CHAOSENSOR CC‑M02 measure?
CC‑M02 measures atmospheric temperature, relative humidity and barometric pressure simultaneously.

2. What output signals are supported by CC‑M02?
It supports analog voltage (0–2V / 0–5V / 0–10V), 4‑20mA current loop, RS485 Modbus‑RTU and SDI‑12 digital output.

3. What radiation shield options are available?
Standard 6‑plate Ø140 mm UV‑stabilized radiation shield with adjustable threaded leveling feet; 8/10/11/12‑plate shields are optional.

4. What is the power supply of CC‑M02?
Standard 12–24 VDC; 3.3 / 5 VDC low‑voltage version can be customized on request.

5. Does CC‑M02 require on‑site calibration?
No. It comes factory pre‑calibrated with full‑range linearisation and thermal compensation for temperature, humidity and pressure. Combine CC‑M02 with other meteorological sensors from our meteorological sensors page to complete your environmental monitoring solution.

This field is required.
This field is required.
This field is required.
This field is required.
This field is required.