| Specification Parameter | Technical Details |
|---|---|
| Model / Series | CC-W11-E Conductivity Sensor (CC-W Series) |
| Key Measurements | Water Electrical Conductivity (EC) & Media Temperature |
| Conductivity Measuring Range | 0∼10000 μS/cm (Custom measurement range available upon request) |
| Measurement Accuracy | ±1.0% FS (Full Scale) |
| Dynamic Response Time | 1 s |
| Sensor 24h Long-term Drift | ≤0.3% FS / 24h |
| Temperature Compensation Profile | Automatic compensation loop (PT1000 or NTC10K selectable options) |
| Total System Power Consumption | <0.2 W (Ultra-low consumption core matrix) |
| Signal Output Interface | Simultaneous Dual Output: RS485 (Modbus-RTU) & 4∼20 mA concurrent loop |
| Power Supply Voltage | 12∼24 VDC wide voltage input |
| Chassis Body Material Options | Durable black ABS housing integrated with built-in industrial graphite electrodes core armor |
| Cable Length | Standard 5m heavy-duty shielded cable (Fully customizable configurations available upon request) |
| Tailored OEM/ODM Capability | • Signal Defense Shield: Advanced anti-polarization & internal magnetic signal isolation technology for superior anti-interference stability. • Brand Customization: Custom silk-screen or laser-engraved logo branding available. • Technical Adaptation: Tailor-made technical parameters, customizable range options, and private-label colored packaging designs. |
| Applications | Ideal for industrial process water tracking, source water monitoring, chemical dosing loops, cooling water networks, and industrial wastewater treatment grids. |
To request the complete PDF technical specifications, please submit your inquiry below.