| Specification Parameter | Technical Details |
|---|---|
| Model | CC-E-G08 Multiparameter Air Quality Sensor |
| Measurement Principle | Multi-sensor fusion premium core combining electrochemical, laser scattering, NDIR, and PID technology |
| Combustible & Base Gases Matrix | |
| Ex (Combustible Gas) | 0-100% LEL | Accuracy: ≤±1%~3% F.S. | Res: 0.1% LEL | T90 ≤10s |
| O₂ (Oxygen) | 0-30% Vol / 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol / 0.1% Vol | T90 ≤10s |
| CO₂ (Carbon Dioxide) | 0-5000ppm / 20% Vol / 100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 1ppm / 0.01% Vol | T90 ≤20s |
| CH₄ (Methane) | 0-100% LEL / 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.1% LEL / 0.01% Vol | T90 ≤10s |
| Common Toxic & Industrial Gases Matrix | |
| CO (Carbon Monoxide) | 0-100ppm / 1000ppm / 2000ppm / 5000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.1ppm / 1ppm | T90 ≤25s |
| H₂S (Hydrogen Sulfide) | 0-50ppm / 100ppm / 2000ppm / 10000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s |
| SO₂ (Sulfur Dioxide) | 0-20ppm / 100ppm / 2000ppm / 10000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s |
| NO (Nitric Oxide) | 0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s |
| NO₂ (Nitrogen Dioxide) | 0-20ppm / 100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤25s |
| O₃ (Ozone) | 0-5ppm / 20ppm / 100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm | T90 ≤20s |
| NH₃ (Ammonia) | 0-50ppm / 100ppm / 5000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s |
| Cl₂ (Chlorine) | 0-20ppm / 100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s |
| HCl (Hydrogen Chloride) | 0-20ppm / 100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s |
| HCN (Hydrogen Cyanide) | 0-30ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| HF (Hydrogen Fluoride) | 0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| PH₃ (Phosphine) | 0-5ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.1ppm | T90 ≤30s |
| F₂ (Fluorine) | 0-1ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s |
| ClO₂ (Chlorine Dioxide) | 0-1ppm / 100ppm / 200ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm / 0.1ppm | T90 ≤30s |
| VOCs & Organic Chemicals Matrix | |
| TVOC / VOC / PID (Photoionization) | 0-10ppm / 100ppm / 2000ppm / 20000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s |
| HCHO (Formaldehyde) | 0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s |
| C₂H₄ (Ethylene) | 0-10ppm / 100ppm / 1000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤50s |
| C₂H₄O (Ethylene Oxide) | 0-20ppm / 100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s |
| C₆H₆ (Benzene) | 0-10ppm / 100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s |
| C₇H₈ (Toluene) | 0-2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 1ppm | T90 ≤30s |
| C₈H₁₀ (Xylene) | 0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.1ppm / 1ppm | T90 ≤30s |
| CH₃Br (Methyl Bromide) | 0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 1ppm | T90 ≤30s |
| CH₃I (Methyl Iodide) | 0-100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| Specialty & Rare Gases Matrix | |
| COCl₂ (Phosgene) | 0-1ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s |
| SiH₄ (Silane) | 0-50ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| AsH₃ (Arsine) | 0-1ppm / 10ppm / 50ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm | T90 ≤30s |
| GeH₄ (Germane) | 0-2ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s |
| B₂H₆ (Diborane) | 0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| N₂H₄ (Hydrazine) | 0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| THT (Tetrahydrothiophene) | 0-100mg/m³ | Accuracy: ≤±1%~3% F.S. | Res: 0.1mg/m³ | T90 ≤60s |
| Br₂ (Bromine) | 0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 1ppm | T90 ≤30s |
| I₂ (Iodine) | 0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| C₄H₆O₂ (Vinyl Acetate) | 0-100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| SO₂F₂ (Sulfuryl Fluoride) | 0-100ppm / 5000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.1ppm / 1ppm | T90 ≤30s |
| CH₃SH (Methyl Mercaptan) | 0-200mg/m³ | Accuracy: ≤±1%~3% F.S. | Res: 0.1mg/m³ | T90 ≤30s |
| He (Helium) | 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol | T90 ≤20s |
| Ar (Argon) | 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol | T90 ≤20s |
| Xe (Xenon) | 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol | T90 ≤20s |
| Hardware & Structural Specifications | |
| Capacity Metrics | Highly customizable arbitrary combination factor tailored per project | Simultaneous multi-channel continuous capture |
| Enclosure Structure | Heavy-duty enhanced outdoor radiation shield (aspiration / multi-plate louvers) casing for ultimate weather protection |
| Mounting Hardware | Included heavy-duty stainless steel U-bolt pole brackets kit |
| Output Signal | RS485 (Modbus-RTU) |
| Power Supply | 12 – 24 VDC |
| Tailored OEM/ODM Capability | Custom parameter combinations, bespoke Technical Matrix setup, private-label laser-engraved branding, and targeted volume pricing brackets. |
| Industrial Applications | Smart city environmental monitoring grids, industrial estate ambient air quality networks, roadside traffic emissions tracking, seaport acoustic & gas assessment, and comprehensive meteorological monitoring stations. |
CC‑E‑G08 Multiparameter Air Quality Sensor
The CC‑E‑G08 Multiparameter Air Quality Sensor is a fully configurable outdoor multi‑gas monitoring unit built on multi‑sensor‑fusion technology including electrochemical, laser scattering, NDIR and PID principles. This CC‑E‑G08 Multiparameter Air Quality Sensor supports arbitrary custom gas‑matrix combinations, covering combustible gas, oxygen, CO₂, toxic industrial gases, VOCs, formaldehyde and specialty rare gases. The CC‑E‑G08 Multiparameter Air Quality Sensor delivers fast T90 response time and accuracy within ±1‑3% full‑scale for selected gas channels. Protected by heavy‑duty enhanced multi‑plate louver solar‑radiation‑shield enclosure, the CC‑E‑G08 Multiparameter Air Quality Sensor maintains stable performance under harsh outdoor climate conditions.
The CC‑E‑G08 Multiparameter Air Quality Sensor transmits all multi‑channel measurement data via RS485 Modbus‑RTU interface for seamless connection with data loggers and SCADA platforms. It operates on standard 12‑24 VDC power supply and comes complete with heavy‑duty stainless‑steel U‑bolt pole‑mounting hardware. The CC‑E‑G08 Multiparameter Air Quality Sensor offers comprehensive OEM and ODM services, including bespoke gas‑matrix setup, private‑label laser‑engraved branding and volume‑based pricing tailored for project‑bidding requirements.
For industrial parks, seaports and outdoor smart‑city environmental grids, fixed single‑gas monitors cannot meet complex multi‑component ambient‑air assessment requirements. The CC‑E‑G08 Multiparameter Air Quality Sensor lets integrators pick only required gas channels without paying for redundant sensing modules. Whether deployed for roadside emission tracking, industrial‑estate air‑quality networks or comprehensive meteorological stations, the CC‑E‑G08 Multiparameter Air Quality Sensor provides continuous, traceable multi‑gas outdoor measurement outputs.
Typical Applications
- Smart‑city outdoor environmental‑monitoring sensor grids
- Industrial‑park multi‑component ambient‑air‑quality networks
- Roadside traffic‑related emission‑effect tracking
- Seaport multi‑gas ambient‑condition assessment
- Professional comprehensive meteorological‑station gas‑monitoring
Frequently Asked Questions
What is multi‑sensor‑fusion gas‑detection?
Multi‑sensor‑fusion combines different sensing cores such as electrochemical, NDIR infrared, PID photoionization and laser‑scattering. Each technology matches specific gas types to balance response speed, resolution and long‑term stability for complex mixed‑gas environments.
Core Advantages & Product Selection Guide
The CC‑E‑G08 Multiparameter Air Quality Sensor provides project‑oriented flexible gas‑channel configuration for outdoor complex‑gas‑scenario monitoring. If you need multi‑gas monitoring for offices, schools and building indoor environments, choose our indoor‑type CC‑E‑G09 Indoor Air Quality Sensor. Browse the full environmental‑instrument portfolio at the environmental smart‑city sensors page.

