| Specification Parameter | Technical Details |
|---|---|
| Model | CC-E-G09 Indoor Air Quality Sensor |
| Key Measurements | Core environmental factors, IAQ tracking parameters, and Gas cluster elements |
| Measurement Principle | High-sensitivity multi-channel sensor integration for refined indoor ambient tracking |
| Combustible & Base Gases Matrix | |
| Ex (Combustible Gas) | 0-100% LEL | Accuracy: ≤±1%~3% F.S. | Res: 0.1% LEL | T90 ≤10s |
| O₂ (Oxygen) | 0-30% Vol / 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol / 0.1% Vol | T90 ≤10s |
| CO₂ (Carbon Dioxide) | 0-5000ppm / 20% Vol / 100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 1ppm / 0.01% Vol | T90 ≤20s |
| CH₄ (Methane) | 0-100% LEL / 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.1% LEL / 0.01% Vol | T90 ≤10s |
| Common Toxic & Industrial Gases Matrix | |
| CO (Carbon Monoxide) | 0-100ppm / 1000ppm / 2000ppm / 5000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.1ppm / 1ppm | T90 ≤25s |
| H₂S (Hydrogen Sulfide) | 0-50ppm / 100ppm / 2000ppm / 10000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s |
| SO₂ (Sulfur Dioxide) | 0-20ppm / 100ppm / 2000ppm / 10000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s |
| NO (Nitric Oxide) | 0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s |
| NO₂ (Nitrogen Dioxide) | 0-20ppm / 100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤25s |
| O₃ (Ozone) | 0-5ppm / 20ppm / 100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm | T90 ≤20s |
| NH₃ (Ammonia) | 0-50ppm / 100ppm / 5000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s |
| Cl₂ (Chlorine) | 0-20ppm / 100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s |
| HCl (Hydrogen Chloride) | 0-20ppm / 100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s |
| HCN (Hydrogen Cyanide) | 0-30ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| HF (Hydrogen Fluoride) | 0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| PH₃ (Phosphine) | 0-5ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.1ppm | T90 ≤30s |
| F₂ (Fluorine) | 0-1ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s |
| ClO₂ (Chlorine Dioxide) | 0-1ppm / 100ppm / 200ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm / 0.1ppm | T90 ≤30s |
| VOCs & Organic Chemicals Matrix | |
| TVOC / VOC / PID (Photoionization) | 0-10ppm / 100ppm / 2000ppm / 20000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s |
| HCHO (Formaldehyde) | 0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s |
| C₂H₄ (Ethylene) | 0-10ppm / 100ppm / 1000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤50s |
| C₂H₄O (Ethylene Oxide) | 0-20ppm / 100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s |
| C₆H₆ (Benzene) | 0-10ppm / 100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s |
| C₇H₈ (Toluene) | 0-2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 1ppm | T90 ≤30s |
| C₈H₁₀ (Xylene) | 0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.1ppm / 1ppm | T90 ≤30s |
| CH₃Br (Methyl Bromide) | 0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 1ppm | T90 ≤30s |
| CH₃I (Methyl Iodide) | 0-100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| Specialty & Rare Gases Matrix | |
| COCl₂ (Phosgene) | 0-1ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s |
| SiH₄ (Silane) | 0-50ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| AsH₃ (Arsine) | 0-1ppm / 10ppm / 50ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm | T90 ≤30s |
| GeH₄ (Germane) | 0-2ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s |
| B₂H₆ (Diborane) | 0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| N₂H₄ (Hydrazine) | 0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| THT (Tetrahydrothiophene) | 0-100mg/m³ | Accuracy: ≤±1%~3% F.S. | Res: 0.1mg/m³ | T90 ≤60s |
| Br₂ (Bromine) | 0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 1ppm | T90 ≤30s |
| I₂ (Iodine) | 0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| C₄H₆O₂ (Vinyl Acetate) | 0-100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| SO₂F₂ (Sulfuryl Fluoride) | 0-100ppm / 5000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.1ppm / 1ppm | T90 ≤30s |
| CH₃SH (Methyl Mercaptan) | 0-200mg/m³ | Accuracy: ≤±1%~3% F.S. | Res: 0.1mg/m³ | T90 ≤30s |
| He (Helium) | 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol | T90 ≤20s |
| Ar (Argon) | 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol | T90 ≤20s |
| Xe (Xenon) | 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol | T90 ≤20s |
| Hardware & Structural Specifications | |
| Capacity Metrics | Highly customizable arbitrary combination factor tailored per biddings | Continuous simultaneous multi-gas capture |
| Enclosure Structure | Premium multi-hole circular dome shell structure designed for natural airflow and indoor aesthetic integration |
| Mounting Hardware | Indoor ceiling or wall-mount hardware with fully customizable cable length available upon request |
| Output Signal | RS485 (Modbus-RTU) |
| Power Supply | 12 – 24 VDC |
| Tailored OEM/ODM Capability | Bespoke parameter matrix combination for project bidding, private-label casing customization, custom cable setups, and tiered volume discounts. |
| Industrial Applications | Smart building HVAC integration, commercial office air networks, school classrooms, hospital indoor air tracking, cleanrooms, and premium residential indoor air quality tracking systems. |
CC‑E‑G09 Indoor Air Quality Sensor
The CC‑E‑G09 Indoor Air Quality Sensor is a multi‑channel configurable IAQ monitoring device designed exclusively for indoor‑ambient tracking. This CC‑E‑G09 Indoor Air Quality Sensor supports highly‑customizable multi‑gas matrix selection covering combustible gases, oxygen, CO₂, toxic industrial gases and VOC‑related organic compounds. The CC‑E‑G09 Indoor Air Quality Sensor delivers fast T90 response and measurement accuracy within ±1‑3% full‑scale for each selected sensing channel. Housed inside premium circular‑dome shell optimized for natural indoor‑airflow and interior aesthetic integration, the CC‑E‑G09 Indoor Air Quality Sensor fits office, classroom and clean‑room installation requirements.
The CC‑E‑G09 Indoor Air Quality Sensor outputs measurement data via RS485 Modbus‑RTU digital bus, easy to integrate with building‑HVAC and smart‑building control systems. It runs on standard 12‑24 VDC power supply and includes dedicated ceiling‑mount and wall‑mount installation hardware. The CC‑E‑G09 Indoor Air Quality Sensor supports full‑range OEM / ODM services: bespoke gas‑matrix combination, private‑label casing customization, custom cable setups and tiered volume‑pricing for commercial‑project bidding. The CC‑E‑G09 Indoor Air Quality Sensor carries out stable simultaneous multi‑gas continuous capture for long‑term indoor‑environment recording.
For smart‑building projects, hospitals and educational facilities, generic fixed‑parameter IAQ sensors often contain many unused channels and waste project‑budget. The CC‑E‑G09 Indoor Air Quality Sensor allows integrators to select exactly the gas parameters required per‑site. Whether you implement HVAC indoor‑air‑quality feedback for commercial offices, classroom environmental tracking, hospital‑ward safety monitoring or clean‑room air‑condition supervision, the CC‑E‑G09 Indoor Air Quality Sensor supplies reliable repeatable indoor multi‑gas measurement results.
Typical Applications
- Smart‑building HVAC indoor‑air‑quality integration systems
- Commercial‑office and open‑workspace air‑quality‑monitoring networks
- School‑classroom and public‑education‑facility environment tracking
- Hospital‑ward and medical‑facility indoor‑safety monitoring
- Clean‑room and premium‑residential indoor‑air‑quality‑systems
Frequently Asked Questions
What is IAQ (Indoor Air Quality)?
IAQ stands for Indoor Air Quality, evaluating air conditions inside enclosed buildings. It covers CO₂, TVOC, toxic‑gas pollutants, temperature and humidity; IAQ data guides ventilation adjustments to protect occupant comfort and health.
Core Advantages & Product Selection Guide
The CC‑E‑G09 Indoor Air Quality Sensor offers flexible project‑specific gas‑channel configuration for building‑indoor multi‑gas‑monitoring tasks. For outdoor industrial‑park and smart‑city multi‑gas‑detection requirements, pair it with our outdoor‑grade CC‑E‑G08 Multiparameter Air Quality Sensor. Explore our full environmental‑sensor lineup from the environmental smart‑city sensors collection.