Chaosensor CC-E-G09 Indoor Air Quality Sensor

CC‑E‑G09 Indoor Air Quality Sensor multi‑gas IAQ monitor for smart‑building indoor environments
Specification Parameter Technical Details
Model CC-E-G09 Indoor Air Quality Sensor
Key Measurements Core environmental factors, IAQ tracking parameters, and Gas cluster elements
Measurement Principle High-sensitivity multi-channel sensor integration for refined indoor ambient tracking
Combustible & Base Gases Matrix
Ex (Combustible Gas)0-100% LEL | Accuracy: ≤±1%~3% F.S. | Res: 0.1% LEL | T90 ≤10s
O₂ (Oxygen)0-30% Vol / 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol / 0.1% Vol | T90 ≤10s
CO₂ (Carbon Dioxide)0-5000ppm / 20% Vol / 100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 1ppm / 0.01% Vol | T90 ≤20s
CH₄ (Methane)0-100% LEL / 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.1% LEL / 0.01% Vol | T90 ≤10s
Common Toxic & Industrial Gases Matrix
CO (Carbon Monoxide)0-100ppm / 1000ppm / 2000ppm / 5000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.1ppm / 1ppm | T90 ≤25s
H₂S (Hydrogen Sulfide)0-50ppm / 100ppm / 2000ppm / 10000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s
SO₂ (Sulfur Dioxide)0-20ppm / 100ppm / 2000ppm / 10000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s
NO (Nitric Oxide)0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s
NO₂ (Nitrogen Dioxide)0-20ppm / 100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤25s
O₃ (Ozone)0-5ppm / 20ppm / 100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm | T90 ≤20s
NH₃ (Ammonia)0-50ppm / 100ppm / 5000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s
Cl₂ (Chlorine)0-20ppm / 100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s
HCl (Hydrogen Chloride)0-20ppm / 100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s
HCN (Hydrogen Cyanide)0-30ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s
HF (Hydrogen Fluoride)0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s
PH₃ (Phosphine)0-5ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.1ppm | T90 ≤30s
F₂ (Fluorine)0-1ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s
ClO₂ (Chlorine Dioxide)0-1ppm / 100ppm / 200ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm / 0.1ppm | T90 ≤30s
VOCs & Organic Chemicals Matrix
TVOC / VOC / PID (Photoionization)0-10ppm / 100ppm / 2000ppm / 20000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s
HCHO (Formaldehyde)0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s
C₂H₄ (Ethylene)0-10ppm / 100ppm / 1000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤50s
C₂H₄O (Ethylene Oxide)0-20ppm / 100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s
C₆H₆ (Benzene)0-10ppm / 100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s
C₇H₈ (Toluene)0-2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 1ppm | T90 ≤30s
C₈H₁₀ (Xylene)0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.1ppm / 1ppm | T90 ≤30s
CH₃Br (Methyl Bromide)0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 1ppm | T90 ≤30s
CH₃I (Methyl Iodide)0-100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s
Specialty & Rare Gases Matrix
COCl₂ (Phosgene)0-1ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s
SiH₄ (Silane)0-50ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s
AsH₃ (Arsine)0-1ppm / 10ppm / 50ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm | T90 ≤30s
GeH₄ (Germane)0-2ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s
B₂H₆ (Diborane)0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s
N₂H₄ (Hydrazine)0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s
THT (Tetrahydrothiophene)0-100mg/m³ | Accuracy: ≤±1%~3% F.S. | Res: 0.1mg/m³ | T90 ≤60s
Br₂ (Bromine)0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 1ppm | T90 ≤30s
I₂ (Iodine)0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s
C₄H₆O₂ (Vinyl Acetate)0-100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s
SO₂F₂ (Sulfuryl Fluoride)0-100ppm / 5000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.1ppm / 1ppm | T90 ≤30s
CH₃SH (Methyl Mercaptan)0-200mg/m³ | Accuracy: ≤±1%~3% F.S. | Res: 0.1mg/m³ | T90 ≤30s
He (Helium)0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol | T90 ≤20s
Ar (Argon)0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol | T90 ≤20s
Xe (Xenon)0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol | T90 ≤20s
Hardware & Structural Specifications
Capacity Metrics Highly customizable arbitrary combination factor tailored per biddings | Continuous simultaneous multi-gas capture
Enclosure Structure Premium multi-hole circular dome shell structure designed for natural airflow and indoor aesthetic integration
Mounting Hardware Indoor ceiling or wall-mount hardware with fully customizable cable length available upon request
Output Signal RS485 (Modbus-RTU)
Power Supply 12 – 24 VDC
Tailored OEM/ODM Capability Bespoke parameter matrix combination for project bidding, private-label casing customization, custom cable setups, and tiered volume discounts.
Industrial Applications Smart building HVAC integration, commercial office air networks, school classrooms, hospital indoor air tracking, cleanrooms, and premium residential indoor air quality tracking systems.
To request the complete PDF technical specifications, please submit your inquiry below.

CC‑E‑G09 Indoor Air Quality Sensor

The CC‑E‑G09 Indoor Air Quality Sensor is a multi‑channel configurable IAQ monitoring device designed exclusively for indoor‑ambient tracking. This CC‑E‑G09 Indoor Air Quality Sensor supports highly‑customizable multi‑gas matrix selection covering combustible gases, oxygen, CO₂, toxic industrial gases and VOC‑related organic compounds. The CC‑E‑G09 Indoor Air Quality Sensor delivers fast T90 response and measurement accuracy within ±1‑3% full‑scale for each selected sensing channel. Housed inside premium circular‑dome shell optimized for natural indoor‑airflow and interior aesthetic integration, the CC‑E‑G09 Indoor Air Quality Sensor fits office, classroom and clean‑room installation requirements.

The CC‑E‑G09 Indoor Air Quality Sensor outputs measurement data via RS485 Modbus‑RTU digital bus, easy to integrate with building‑HVAC and smart‑building control systems. It runs on standard 12‑24 VDC power supply and includes dedicated ceiling‑mount and wall‑mount installation hardware. The CC‑E‑G09 Indoor Air Quality Sensor supports full‑range OEM / ODM services: bespoke gas‑matrix combination, private‑label casing customization, custom cable setups and tiered volume‑pricing for commercial‑project bidding. The CC‑E‑G09 Indoor Air Quality Sensor carries out stable simultaneous multi‑gas continuous capture for long‑term indoor‑environment recording.

For smart‑building projects, hospitals and educational facilities, generic fixed‑parameter IAQ sensors often contain many unused channels and waste project‑budget. The CC‑E‑G09 Indoor Air Quality Sensor allows integrators to select exactly the gas parameters required per‑site. Whether you implement HVAC indoor‑air‑quality feedback for commercial offices, classroom environmental tracking, hospital‑ward safety monitoring or clean‑room air‑condition supervision, the CC‑E‑G09 Indoor Air Quality Sensor supplies reliable repeatable indoor multi‑gas measurement results.

Typical Applications

  • Smart‑building HVAC indoor‑air‑quality integration systems
  • Commercial‑office and open‑workspace air‑quality‑monitoring networks
  • School‑classroom and public‑education‑facility environment tracking
  • Hospital‑ward and medical‑facility indoor‑safety monitoring
  • Clean‑room and premium‑residential indoor‑air‑quality‑systems

Frequently Asked Questions

What is IAQ (Indoor Air Quality)?

IAQ stands for Indoor Air Quality, evaluating air conditions inside enclosed buildings. It covers CO₂, TVOC, toxic‑gas pollutants, temperature and humidity; IAQ data guides ventilation adjustments to protect occupant comfort and health.

Core Advantages & Product Selection Guide

The CC‑E‑G09 Indoor Air Quality Sensor offers flexible project‑specific gas‑channel configuration for building‑indoor multi‑gas‑monitoring tasks. For outdoor industrial‑park and smart‑city multi‑gas‑detection requirements, pair it with our outdoor‑grade CC‑E‑G08 Multiparameter Air Quality Sensor. Explore our full environmental‑sensor lineup from the environmental smart‑city sensors collection.

This field is required.
This field is required.
This field is required.
This field is required.
This field is required.