| Specification Parameter | Technical Details |
|---|---|
| Model | CC-E-G10 Fixed Industrial Gas Detector |
| Key Measurements | Combustible gases, Toxic gases, VOCs, and Rare/Specialty gases (Single or multi-gas combination) |
| Measurement Principle | Premium catalytic combustion, electrochemical, PID, or non-dispersive infrared (NDIR) core technologies |
| Gas Matrix: Combustible & Base Gases | |
| Ex (Combustible Gas) | 0-100% LEL | Accuracy: ≤±1%~3% F.S. | Res: 0.1% LEL | T90 ≤10s |
| O₂ (Oxygen) | 0-30% Vol / 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol / 0.1% Vol | T90 ≤10s |
| CO₂ (Carbon Dioxide) | 0-5000ppm / 20% Vol / 100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 1ppm / 0.01% Vol | T90 ≤20s |
| CH₄ (Methane) | 0-100% LEL / 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.1% LEL / 0.01% Vol | T90 ≤10s |
| Gas Matrix: Common Toxic & Industrial Gases | |
| CO (Carbon Monoxide) | 0-100ppm / 1000ppm / 2000ppm / 5000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.1ppm / 1ppm | T90 ≤25s |
| H₂S (Hydrogen Sulfide) | 0-50ppm / 100ppm / 2000ppm / 10000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s |
| SO₂ (Sulfur Dioxide) | 0-20ppm / 100ppm / 2000ppm / 10000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s |
| NO (Nitric Oxide) | 0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s |
| NO₂ (Nitrogen Dioxide) | 0-20ppm / 100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤25s |
| O₃ (Ozone) | 0-5ppm / 20ppm / 100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm | T90 ≤20s |
| NH₃ (Ammonia) | 0-50ppm / 100ppm / 5000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s |
| Cl₂ (Chlorine) | 0-20ppm / 100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s |
| HCl (Hydrogen Chloride) | 0-20ppm / 100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s |
| HCN (Hydrogen Cyanide) | 0-30ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| HF (Hydrogen Fluoride) | 0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| PH₃ (Phosphine) | 0-5ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.1ppm | T90 ≤30s |
| F₂ (Fluorine) | 0-1ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s |
| ClO₂ (Chlorine Dioxide) | 0-1ppm / 100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm / 0.1ppm | T90 ≤30s |
| Gas Matrix: VOCs & Organic Chemicals | |
| TVOC / VOC / PID (Photoionization) | 0-10ppm / 100ppm / 2000ppm / 20000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s |
| HCHO (Formaldehyde) | 0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s |
| C₂H₄ (Ethylene) | 0-10ppm / 100ppm / 1000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤50s |
| C₂H₄O (Ethylene Oxide) | 0-20ppm / 100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s |
| C₆H₆ (Benzene) | 0-10ppm / 100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s |
| C₇H₈ (Toluene) | 0-2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 1ppm | T90 ≤30s |
| C₈H₁₀ (Xylene) | 0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.1ppm / 1ppm | T90 ≤30s |
| CH₃Br (Methyl Bromide) | 0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 1ppm | T90 ≤30s |
| CH₃I (Methyl Iodide) | 0-100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| Gas Matrix: Specialty & Rare Gases | |
| COCl₂ (Phosgene) | 0-1ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s |
| SiH₄ (Silane) | 0-50ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| AsH₃ (Arsine) | 0-1ppm / 10ppm / 50ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm | T90 ≤30s |
| GeH₄ (Germane) | 0-2ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s |
| B₂H₆ (Diborane) | 0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| N₂H₄ (Hydrazine) | 0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| THT (Tetrahydrothiophene) | 0-100mg/m³ | Accuracy: ≤±1%~3% F.S. | Res: 0.1mg/m³ | T90 ≤60s |
| Br₂ (Bromine) | 0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 1ppm | T90 ≤30s |
| I₂ (Iodine) | 0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| C₄H₆O₂ (Vinyl Acetate) | 0-100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s |
| SO₂F₂ (Sulfuryl Fluoride) | 0-100ppm / 5000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.1ppm / 1ppm | T90 ≤30s |
| CH₃SH (Methyl Mercaptan) | 0-200mg/m³ | Accuracy: ≤±1%~3% F.S. | Res: 0.1mg/m³ | T90 ≤30s |
| He (Helium) | 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol | T90 ≤20s |
| Ar (Argon) | 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol | T90 ≤20s |
| Xe (Xenon) | 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol | T90 ≤20s |
| Hardware & Technical Environments | |
| Capacity Metrics | Low-power consumption | High selectivity & repeatability • Operating environment: -20 to +55℃ (Typical), -40℃ to +70℃ (Limit) • Humidity: 10~95%RH |
| Enclosure Structure | Heavy-duty explosion-proof cast aluminum casing available in Grey, Yellow, Orange, Red, or Random selection |
| Display Configuration | Base quotation is for blind version | Optional integrated screen setup available |
| Alarm Method | Optional top-mounted sound & light alarm strobe |
| Mounting Hardware | Wall-mounted brackets or heavy-duty pipe-mounting hardware configurations available upon request |
| Output Signal | Standard 3-wire 4–20mA analog output / Bus-system RS485 (Modbus-RTU) digital loop |
| Power Supply | 24 VDC |
| Tailored OEM/ODM Capability | Flexible screen or blind terminal configuration, custom gas combination setups, specified casing shell colors and logos, and scalable pricing tiers for bulk project biddings. |
| Industrial Applications | Chemical processing plants, oil & gas refineries, underground utility tunnels, industrial boiler rooms, hazardous waste facilities, metallurgical factories, and smart environment tracking networks. |
CC‑E‑G10 Fixed Industrial Gas Detector
The CC‑E‑G10 Fixed Industrial Gas Detector is an explosion‑proof stationary gas‑leak‑monitoring transmitter built for industrial safety scenarios. This CC‑E‑G10 Fixed Industrial Gas Detector adopts catalytic‑combustion, electrochemical, PID and NDIR core sensing technologies, supporting single‑gas or mixed multi‑gas combinations covering combustible gases, toxic agents, VOCs and specialty rare gases. The CC‑E‑G10 Fixed Industrial Gas Detector delivers measurement accuracy within ±1‑3% full‑scale and fast T90 response time, with stable performance under‑20℃~+55℃ typical operating environment, extending to‑40℃~+70℃ limit condition at 10‑95%RH humidity range. Housed in heavy‑duty cast‑aluminum explosion‑proof shell, the CC‑E‑G10 Fixed Industrial Gas Detector supports multiple optional casing colors for site‑specific requirements.
The CC‑E‑G10 Fixed Industrial Gas Detector offers flexible hardware configurations: blind basic version, optional local display module and top‑mount sound‑light alarm strobe. It provides dual output options: 3‑wire 4‑20 mA analog signal and RS485 Modbus‑RTU digital bus, powered by 24 VDC. Wall‑mount or pipe‑mount installation kits are supplied for field deployment. The CC‑E‑G10 Fixed Industrial Gas Detector supports comprehensive OEM / ODM services including custom gas matrix selection, casing color customization, logo marking and volume‑oriented bidding pricing for large‑scale industrial projects.
For chemical plants, oil‑gas refineries and confined utility tunnels, portable intermittent gas inspection cannot deliver 24/7 continuous hazard warning. The CC‑E‑G10 Fixed Industrial Gas Detector runs round‑the‑clock to capture rising hazardous‑gas concentrations and feed real‑time data to safety control systems. Whether deployed inside processing workshops, boiler houses, hazardous‑waste facilities or metallurgical sites, the CC‑E‑G10 Fixed Industrial Gas Detector supplies reliable repeatable gas‑leak monitoring results for on‑site occupational‑safety protection.
Typical Applications
- Chemical‑processing‑plant hazardous‑gas continuous‑leak surveillance
- Oil & gas refinery and petrochemical‑site safety monitoring
- Underground utility tunnel confined‑space gas‑hazard early warning
- Industrial boiler‑room combustible‑toxic‑gas safety‑detection
- Hazardous‑waste facilities and metallurgical‑factory gas‑monitoring networks
Frequently Asked Questions
What is explosion‑proof gas detector for industrial sites?
Explosion‑proof gas detectors adopt reinforced cast‑aluminum enclosure, preventing internal electrical‑spark ignition from triggering combustion or explosion in flammable‑gas‑rich industrial environments, which is mandatory safety hardware for chemical and petrochemical zones.
Core Advantages & Product Selection Guide
The CC‑E‑G10 Fixed Industrial Gas Detector provides rugged explosion‑proof continuous fixed‑point gas‑leak detection for high‑risk industrial zones. If you need cabinet‑type pump‑suction multi‑parameter ambient air‑quality monitoring for whole‑site environmental assessment, pair it with our CC‑E‑AQM Air Quality Monitoring Station. Explore full environmental‑sensor product lineup at the environmental smart‑city sensors page.