Chaosensor CC-E-AQM Air Quality Monitoring Station

CC‑E‑AQM Air Quality Monitoring Station pump‑suction modular outdoor ambient air monitoring station
Specification Parameter Technical Details
Model CC-E-AQM Air Quality Monitoring Station
Key Measurements Gas pollutants, Dust/PM, Meteorological parameters, Ambient noise, Illuminance
Measurement Principle Premium active pump-suction loop for fully automated climate and gas monitoring
Configuration Type Fully modular sensor matrix engineered for customized spec audit (Range & Resolution are fully customizable)
Meteo & Core Parameters (Optional) Wind speed, Wind direction, Temperature, Humidity, Barometric pressure, Lux, Noise
Gas Matrix: Combustible & Base Gases (Optional)
Ex (Combustible Gas)0-100% LEL | Accuracy: ≤±1%~3% F.S. | Res: 0.1% LEL | T90 ≤10s
O₂ (Oxygen)0-30% Vol / 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol / 0.1% Vol | T90 ≤10s
CO₂ (Carbon Dioxide)0-5000ppm / 20% Vol / 100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 1ppm / 0.01% Vol | T90 ≤20s
CH₄ (Methane)0-100% LEL / 0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.1% LEL / 0.01% Vol | T90 ≤10s
Gas Matrix: Common Toxic & Industrial Gases (Optional)
CO (Carbon Monoxide)0-100ppm / 1000ppm / 2000ppm / 5000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.1ppm / 1ppm | T90 ≤25s
H₂S (Hydrogen Sulfide)0-50ppm / 100ppm / 2000ppm / 10000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s
SO₂ (Sulfur Dioxide)0-20ppm / 100ppm / 2000ppm / 10000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s
NO (Nitric Oxide)0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s
NO₂ (Nitrogen Dioxide)0-20ppm / 100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤25s
O₃ (Ozone)0-5ppm / 20ppm / 100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm | T90 ≤20s
NH₃ (Ammonia)0-50ppm / 100ppm / 5000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s
Cl₂ (Chlorine)0-20ppm / 100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s
HCl (Hydrogen Chloride)0-20ppm / 100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s
HCN (Hydrogen Cyanide)0-30ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s
HF (Hydrogen Fluoride)0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s
PH₃ (Phosphine)0-5ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.1ppm | T90 ≤30s
F₂ (Fluorine)0-1ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s
ClO₂ (Chlorine Dioxide)0-1ppm / 100ppm / 200ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm / 0.1ppm | T90 ≤30s
Gas Matrix: VOCs & Organic Chemicals (Optional)
TVOC / VOC / PID (Photoionization)0-10ppm / 100ppm / 2000ppm / 20000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s
HCHO (Formaldehyde)0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s
C₂H₄ (Ethylene)0-10ppm / 100ppm / 1000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤50s
C₂H₄O (Ethylene Oxide)0-20ppm / 100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm | T90 ≤30s
C₆H₆ (Benzene)0-10ppm / 100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 0.1ppm / 1ppm | T90 ≤30s
C₇H₈ (Toluene)0-2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 1ppm | T90 ≤30s
C₈H₁₀ (Xylene)0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.1ppm / 1ppm | T90 ≤30s
CH₃Br (Methyl Bromide)0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 1ppm | T90 ≤30s
CH₃I (Methyl Iodide)0-100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s
Gas Matrix: Specialty & Rare Gases (Optional)
COCl₂ (Phosgene)0-1ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm | T90 ≤30s
SiH₄ (Silane)0-50ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s
AsH₃ (Arsine)0-1ppm / 10ppm / 50ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm | T90 ≤30s
GeH₄ (Germane)0-2ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.001ppm / 0.01ppm | T90 ≤30s
B₂H₆ (Diborane)0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s
N₂H₄ (Hydrazine)0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s
THT (Tetrahydrothiophene)0-100mg/m³ | Accuracy: ≤±1%~3% F.S. | Res: 0.1mg/m³ | T90 ≤60s
Br₂ (Bromine)0-100ppm / 2000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm / 1ppm | T90 ≤30s
I₂ (Iodine)0-10ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s
C₄H₆O₂ (Vinyl Acetate)0-100ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.01ppm | T90 ≤30s
SO₂F₂ (Sulfuryl Fluoride)0-100ppm / 5000ppm | Accuracy: ≤±1%~3% F.S. | Res: 0.1ppm / 1ppm | T90 ≤30s
CH₃SH (Methyl Mercaptan)0-200mg/m³ | Accuracy: ≤±1%~3% F.S. | Res: 0.1mg/m³ | T90 ≤30s
He (Helium)0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol | T90 ≤20s
Ar (Argon)0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol | T90 ≤20s
Xe (Xenon)0-100% Vol | Accuracy: ≤±1%~3% F.S. | Res: 0.01% Vol | T90 ≤20s
System & Hardwares Matrix
Output Signal RS485 (Modbus-RTU)
Power Supply 12 – 24 VDC
Tailored OEM/ODM Capability Custom silk-screen or laser-engraved logo branding, tailor-made technical parameters and output signals, and private-label colored packaging designs.
Industrial Applications Smart city environmental IoT networks, industrial estate air quality monitoring, factory perimeter hazardous gas detection, environmental impact assessments, and traffic emissions tracking.
To request the complete PDF technical specifications, please submit your inquiry below.

CC‑E‑AQM Air Quality Monitoring Station

The CC‑E‑AQM Air Quality Monitoring Station is a cabinet‑style ambient‑air‑quality system built around active pump‑suction sampling loop for automated outdoor environmental surveillance. This CC‑E‑AQM Air Quality Monitoring Station adopts fully‑modular sensor‑matrix architecture, allowing fully‑customizable range and resolution setup per‑project. The CC‑E‑AQM Air Quality Monitoring Station supports optional measurement of gaseous pollutants, particulate dust‑PM series, noise, illuminance and full meteorological indicators including wind speed, wind direction, temperature, humidity and barometric pressure. Every selected sensing channel delivers accuracy within ±1‑3% full‑scale with fast T90 response for reliable continuous field sampling.

The CC‑E‑AQM Air Quality Monitoring Station outputs all integrated multi‑parameter datasets via RS485 Modbus‑RTU digital bus for seamless connection with SCADA, data‑logger and IoT cloud platforms. Powered by standard 12‑24 VDC supply, the CC‑E‑AQM Air Quality Monitoring Station supports comprehensive OEM and ODM services including custom laser‑engraved logo marking, bespoke technical‑matrix adjustment and private‑label packaging tailored for bidding and large‑scale network‑construction projects.

For smart‑city IoT grids, industrial‑park perimeter safety supervision and environmental‑impact‑assessment work, simple dispersed diffusive sensors struggle to deliver stable sample intake under low‑wind conditions. The CC‑E‑AQM Air Quality Monitoring Station uses pump‑driven suction to draw ambient air steadily into sensing chambers, obtaining consistent measurement results even in poor‑ventilation surroundings. Whether deployed for factory‑boundary hazardous‑gas early‑warning, roadside‑traffic‑emission tracing or regional environmental‑research recording, the CC‑E‑AQM Air Quality Monitoring Station supplies traceable multi‑factor ambient‑air‑quality outputs.

Typical Applications

  • Smart‑city large‑scale environmental‑IoT monitoring sensor networks
  • Industrial‑estate perimeter multi‑pollutant air‑quality supervision
  • Factory site boundary hazardous‑gas leak‑detection and early warning
  • Project‑based environmental‑impact‑assessment field‑monitoring tasks
  • Roadside traffic‑related exhaust‑emission tracking and data logging

Frequently Asked Questions

What is pump‑suction sampling for air‑quality monitoring?

Pump‑suction (active sampling) uses built‑in air‑pumps to actively draw ambient air into sensor chambers, instead of relying only on natural wind diffusion. It stabilizes sample intake and improves data repeatability under low‑wind or stagnant‑air outdoor conditions.

Core Advantages & Product Selection Guide

The CC‑E‑AQM Air Quality Monitoring Station delivers complete pump‑suction modular multi‑factor outdoor air‑quality monitoring. If you need compact distributed multi‑gas sensing without cabinet‑type pump‑sampling, select our CC‑E‑G08 Multiparameter Air Quality Sensor. Explore the full environmental‑instrument portfolio on the environmental smart‑city sensors page.

This field is required.
This field is required.
This field is required.
This field is required.
This field is required.